Review



cryoholder model 626  (Gatan Inc)


Bioz Verified Symbol Gatan Inc is a verified supplier
Bioz Manufacturer Symbol Gatan Inc manufactures this product  
  • Logo
  • About
  • News
  • Press Release
  • Team
  • Advisors
  • Partners
  • Contact
  • Bioz Stars
  • Bioz vStars
  • 86

    Structured Review

    Gatan Inc cryoholder model 626
    Cryoholder Model 626, supplied by Gatan Inc, used in various techniques. Bioz Stars score: 86/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/model+626+cryoholder/chem_rxiv___2022___t862c-171-8-11
    Average 86 stars, based on 1 article reviews
    cryoholder model 626 - by Bioz Stars, 2026-09
    86/100 stars

    Images

    Related Articles

    Microscopy:

    Article Title: Cryo-electron microscopy of trichocyte (hard alpha-keratin) intermediate filaments reveals a low-density core.
    Article Snippet: Trichocyte intermediate filaments (IF) are the principal components of epidermal appendages such as hair and nail.. Based on studies by a variety of techniques, it has been inferred that trichocyte IF are structurally similar to other kinds of IF.. However, some basic structural attributes have yet to be established: in particular, it has remained unclear whether IF are hollow.

    Article Title: The cryptophycin-tubulin ring structure indicates two points of curvature in the tubulin dimer.
    Article Snippet: Cryptophycin-1 is the parent compound of a group of cyclic peptides with potent antineoplastic activity.. Cryptophycins are thought to function by modulating the dynamic instability of spindle microtubules, and in vitro are known to bind in an equimolar ratio to the â-tubulin subunit and to induce the formation of ring-like complexes.. However, the detailed mechanisms whereby the cryptophycins interact with tubulin are not known.

    Article Title: Three-dimensional structure of poliovirus receptor bound to poliovirus
    Article Snippet: .. Focal pairs of micrographs were recorded on a Philips CM200-FEG electron microscope (FEI, Mahwah, NJ), equipped with a model 626 cryoholder (Gatan, Pleasanton, CA). ..

    Article Title: Internal Proteins of the Procapsid and Mature Capsids of Herpes Simplex Virus 1 Mapped by Bubblegram Imaging
    Article Snippet: In a typical experiment, a 3.5-μl drop of sample was applied to an EM grid bearing a glow-discharged continuous thin carbon film and after 1 min was blotted to a thin film and then vitrified using a Leica EM GP cryostation. .. The grid was transferred into a Gatan model 626 cryoholder, and micrographs were recorded on a CM200-FEG transmission electron microscope (FEI), operating at 120 keV and a magnification of ×38,000, with a nominal defocus (Δf) of ∼−1.9 μm. .. Data were recorded on film (Kodak SO-163).

    other:

    Article Title: Direct Visualization by Cryo-EM of the Mycobacterial Capsular Layer: A Labile Structure Containing ESX-1-Secreted Proteins
    Article Snippet: Grids were transferred to a Gatan model 626 cryoholder (Gatan, Pleasanton, CA) under liquid nitrogen and inserted into a Tecnai 12 (FEI, Eindhoven, Netherlands) operating at 120 kV.

    Transmission Electron Microscopy:

    Article Title: Aqueous solution behaviour of novel water-soluble amphiphilic copolymers with elevated hydrophobic unit content
    Article Snippet: A series of water-soluble statistical copolymers poly(OEGMA-stat-styrene) and block copolymers poly(OEGMAstat-styrene)-b-PDMAPMA have been synthesized via RAFT polymerization.. Despite the polymers having a relatively high styrene content they are readily soluble in water, capable of forming transparent solutions at room temperature without resort to conventional solvent-exchange methods.. 1 H DOSY NMR, dynamic light scattering, transmission electron microscopy and atomic force microscopy indicate that the copolymers containing high styrene content formed nanoaggregates less than 15 nm in diameter.

    Transmission Assay:

    Article Title: Internal Proteins of the Procapsid and Mature Capsids of Herpes Simplex Virus 1 Mapped by Bubblegram Imaging
    Article Snippet: In a typical experiment, a 3.5-μl drop of sample was applied to an EM grid bearing a glow-discharged continuous thin carbon film and after 1 min was blotted to a thin film and then vitrified using a Leica EM GP cryostation. .. The grid was transferred into a Gatan model 626 cryoholder, and micrographs were recorded on a CM200-FEG transmission electron microscope (FEI), operating at 120 keV and a magnification of ×38,000, with a nominal defocus (Δf) of ∼−1.9 μm. .. Data were recorded on film (Kodak SO-163).



    Similar Products

    86
    Gatan Inc cryoholder model 626
    Cryoholder Model 626, supplied by Gatan Inc, used in various techniques. Bioz Stars score: 86/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/model+626+cryoholder/chem_rxiv___2022___t862c-171-8-11
    Average 86 stars, based on 1 article reviews
    cryoholder model 626 - by Bioz Stars, 2026-09
    86/100 stars
      Buy from Supplier

    86
    Gatan Inc model 626 cryoholder
    Model 626 Cryoholder, supplied by Gatan Inc, used in various techniques. Bioz Stars score: 86/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/model+626+cryoholder/10__1039_slash_c7py00832e-102-28-27
    Average 86 stars, based on 1 article reviews
    model 626 cryoholder - by Bioz Stars, 2026-09
    86/100 stars
      Buy from Supplier

    Image Search Results